Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Company News
Home Products12V Rechargeable Battery Pack

Safe UPS 100Ah 12V Rechargeable Battery Pack Solar Emergency Power Supply

Good quality Lifepo4 Battery Pack for sales
Good quality Lifepo4 Battery Pack for sales
The shipment day is a litter bit late.but it is ok.all good were perfect.hope next cooperation.ths very much.

—— Greg Henk

We have received the battery packs and performing tests have passed . We are impressed by the assembly. it is almost the best one . thank you

—— Alexander Kozhushko

I'm Online Chat Now

Safe UPS 100Ah 12V Rechargeable Battery Pack Solar Emergency Power Supply

China Safe UPS 100Ah 12V Rechargeable Battery Pack Solar Emergency Power Supply supplier
Safe UPS 100Ah 12V Rechargeable Battery Pack Solar Emergency Power Supply supplier Safe UPS 100Ah 12V Rechargeable Battery Pack Solar Emergency Power Supply supplier Safe UPS 100Ah 12V Rechargeable Battery Pack Solar Emergency Power Supply supplier Safe UPS 100Ah 12V Rechargeable Battery Pack Solar Emergency Power Supply supplier

Large Image :  Safe UPS 100Ah 12V Rechargeable Battery Pack Solar Emergency Power Supply

Product Details:

Place of Origin: CHINA
Brand Name: HKANON
Certification: CE RoHS MSDS UN38.3
Model Number: Battery Lithium 12V 100Ah

Payment & Shipping Terms:

Minimum Order Quantity: 1
Packaging Details: 1PC/Carton
Delivery Time: 7 work days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 10K/Month
Contact Now
Detailed Product Description
Type: Li-Ion,Lifepo4 Size: 350(W)x270(H)x155mm(W)
Warranty: 1 Year,12 Months,2 Years Cycle Life: 2000 Cycles DOD>80%
Nominal Capacity: Customized,50AH Color: Blue,Blue Or Others

Custom 12V Rechargeable Battery Pack UPS Power Safe Battery Lithium 12V 100Ah

 

Possible dangers
Risk of short circuit and the subsequent fire
Charged and uncharged cells contain large amount of electricity, which can cause a short-circuit in the electrical spark or arc. The battery itself is not combustible, but from incandescent contacts may ignite other combustible materials.
Risk of injury by DC
When connecting more cells and batteries in series increases the risk of injury DC. In any case, do not touch electrical wires or other components under voltage.
Risk of chemicals
Lithium cells and batteries contain no caustics and acids. However contain chemical substances, that act on the human body. For this reason, in the handling of cells and batteries must observe the following rules:
Eye protection: protect your eyes with goggles against the ingress of chemicals in the eye.
Skin protection: wear protective clothing and gloves. Avoid skin contact with chemicals.
Protection against inhalation: Operate with batteries only in well-ventilated areas. In enclosed spaces it is necessary to provide forced air ventilation.

 

Charging

warning
WARNING: Carefully check the maximum voltage as specified cells or batteries. Exceeding the voltage will damage the battery and void the warranty.

Initial charging
New batteries LFP/LFYP are partly charged from factory. However, before first use it is absolutely necessary to charge the battery to full capacity. This initial charging should be done at maximum current of 1C and the voltage level according to the specification of the cell or battery. Please see specifications of the cell about value of initial charging. Battery capacity in the first cycle gradually grows. In the first few cycles is recommended to avoid rapid discharge to the minimum capacity and we do not recommend quick charging. After about the fifth, sixth cycle, is nothing to prevent the batteries used in full operating cycle according to the manufacturer's specifications for the type of battery.

Standard charging
Because LiFePO4 batteries has no memory effect, charging can be done at any time. Repeated short charge cycles the battery life not significantly changed (within + / - 5%).

 

Discharging

warning
WARNING: Carefully check the minimum voltage as specified cells or batteries. Discharging below this voltage will damage the battery and void the warranty.


Maximum discharging currents for single cells or batteries are listed in the manufacturer's specifications for the type of cell.

Battery and cell checking

Battery check and match any individual cell or battery is done by charging the cells in series, connecting the charger to each individual battery. Checking the battery status and any match is recommended to perform these intervals (ie, discharge / charge cycle):
first charge
after the first cycle
after the 5 cycles
after the 20 cycles
after the 50 cycles
possibly followed by further the anomalies detected about once every 50 to 200 cycles

 

BMS

Each Battery a built-in BMS. This BMS is a high-tech design that manage two main aspects of battery during operation :Protection features :
Low Voltage Protection Switch – Automatically disconnects at 10.0V
Over Voltage Protection Switch – Automatically disconnects at 15.0V

 

Specifications Battery Lithium 12V 100Ah 
Cells 3.2V 100Ah Sinopoly Prismatic Cells
Power Customized
Nominal capacity 100Ah 
Nominal voltage 12.8V 
Size and Weight 350(W)x270(H)x155mm(W) 
Charge Temperature Range 0-45C
Discharge Temperature Range -20-60C
PCM/BMS Including and Accept to OEM/ODM
Case ABS Case
Charging cycles +2000 times
Application Motorcycle,golf cart.Power supply ,Solar system 
Features Small Volume,Long Cycle Life, High Safety,Environmental Protection

 

Safe UPS 100Ah 12V Rechargeable Battery Pack Solar Emergency Power SupplySafe UPS 100Ah 12V Rechargeable Battery Pack Solar Emergency Power SupplySafe UPS 100Ah 12V Rechargeable Battery Pack Solar Emergency Power SupplySafe UPS 100Ah 12V Rechargeable Battery Pack Solar Emergency Power Supply

 

 

Contact Details
Shenzhen Herculesi Technology Co., Ltd.

Contact Person: Sales Manager

Tel: +8613632987139

Send your inquiry directly to us (0 / 3000)

Other Products